Coaxial Cables | ||||||||||||
LCX32(1-1/4″) L
Construction
Inner conductor | Smooth coppertube | Φ13.0mm |
---|---|---|
Dielectric | Foam PE | Φ33.0mm |
Outer conductor | Corrugated copper tubeandslot | Φ36.0mm |
Sheath | PE/LSOH | Φ38.6mm |
Electrical & Mechanical Characteristics
Impedance :50±3Ohm
Nominal capacitance :76pF/m
Velocity of propagation :89%
Insulation resistance :>5000Mohm.Km
Inner conductor resistance :0.7 Ohm/Km
Outer conductor resistance :0.7Ohm/Km
Installation temperature range :-40°C-+60°C
Operating temperature range :-55°C-+85°C
Cable weight(approx.) :1050kg/km/1150kg/km
Attenuation
Frequency(MHz) | Attenuation(dB/100m) | Attenuation(dB/100ft) |
---|---|---|
75 | 0.8 | 0.24 |
150 | 1.1 | 0.34 |
450 | 2.5 | 0.76 |
800 | 3.3 | 1.01 |
900 | 3.5 | 1.07 |
1800 | 5 | 1.52 |
2200 | 5.9 | 1.8 |
2400 | 6.5 | 1.98 |